WONIK PNE has test solutions for a battery pack including pack cycler, EOL line and others.

DAQ
(Isolated Type)
As an isolation type DAQ,
a device to measure cell temperature or voltage in the battery pack.

Overview

  • Data protection and results saving and backup in case of power shutdown
  • Measurable Pack Voltage : Up to 1,000V
  • Test result storage and research by user defined criteria
  • Measurable Cell Voltage : Up tp 5V
  • Temperature Measurement with type K thermocouples

Specification

제품사양
Functions Specifications
Cell voltage Measurement Type Isolated
Cell voltage Measurement Reading Range 0~5V
Cell voltage Measurement Reading Accuracy ≥±0.1% (Full Scale)
Cell voltage Measurement Channel Range Expandable to 8 Channel unit
Cell voltage Measurement Channel Max Range 512 Channel
Cell Temperature Measurement Sensor Type K- type Thermocouple Wire, RTD
Cell Temperature Measurement Reading Range -50℃ ~ +200℃ (K-type)
Cell Temperature Measurement Reading Accuracy ≥±1℃
Cell Temperature Measurement Channel Range Expandable to 10 Channel unit
Cell Temperature Measurement Channel Max Range 100 Channel

Contact us

  • PACK CYCLER