- FPSC (Fuel Cell/Redox Flow Battery Cycler)
- Performance test equipment of Fuel cells ,Flow stack or Redox flow batteries. It’s able to do high capacity dynamic simulation and be operated in an independent or parallel mode by an energy regeneration method.
Overview
Model FPSC is optimized for Fuel cells, Flow stacks or Redox flow batteries. It can be measure cell voltage and temperature in the battery pack using auxiliary sensor. It is also possible to test all other batteries that have a charging voltage above 10 V and be able to do high capacity dynamic simulation.
- Performance Tests of Fuel cell, Flow stacks or Redox flow batteries
- Interlock with hot/cold chamber
- Voltage Range: 5~100V
- Response Rising Time : ≤5ms
- Current Range : 50~2,000A (in parallel)
- Response Falling Time : ≤5ms (Non Overshoot)
- Accuracy & Resolution V/I Accuracy : ±0.05%
- AC Power Quality Power Factor : ≥0.99 (Option : 0.98)
- Accuracy & Resolution V/I Resolution : 18,24bits
- AC Power Quality Ithd : ≤3% (Rated Power)
- Accuracy & Resolution I Ripple : ≤±0.1% (F.S)
- Options :
DAQ, Temperature Logging, Chamber control, Chiller control, Cell balancing - AC Input : 3Phase, 220 or 380 or 440Vac, 50/60Hz
(Able to be changed depending on installation conditions) - BMS (Battery Management System) :
CAN,CAN FD RS-485, Ethernet, SMBUS, I2C, LIN, FlexRay
Specification
WONIK PNE can be configured with a wide range of voltage and current ranges and can be fitted with optional hardware to provide a number of additional features and capabilities.
Model Designation | Voltage | Current | Max. Number of Channels | Max. Number of Parallel | Options |
---|---|---|---|---|---|
FPSC 50 | 5~50Vdc | 50~1,000Adc (Max.2,000Adc) | 4 | 4 | -50~50Vdc |
FPSC 100 | 5~100Vdc | 50~1,000Adc (Max.2,000Adc) | 4 | 4 | -100~100Vdc |
Option
Funtions | Specifications | |
---|---|---|
AUX VOLT. MEASUREMENT | Reading Range | 0~5V |
AUX VOLT. MEASUREMENT | Reading Accuracy | ≥±0.05% (Full Scale) |
AUX VOLT. MEASUREMENT | Channel Range | Expandable to 8 Channel unit |
TEMP. MEASUREMENT | Sensor Type | K-Type Thermocouple Wire, RTD |
TEMP. MEASUREMENT | Reading Range | -50℃ ~ +200℃ (K-type) |
TEMP. MEASUREMENT | Reading Accuracy | ≥±1℃ |
TEMP. MEASUREMENT | Channel Range | Expandable to 10 Channel unit |
Application
RFB (Redox Flow Battery)
Fuel Cell
Contact us
- PACK CYCLER