- HBRC (High Speed Regenerative Cycler)
- Battery Discharge Enery Refeneration with *high speed
Current ranges : 10~400A
Overview
Model. LTC is available in sizes from 8 to 32 test Cells and are custom manufactured to meet specific customer's requirements.They can be used 3 electrode power cell test with auxiliary voltage and can be saved to 1m/s.
- Type : Regenerative
- Control Mode: CV, CC, CP, CR, CCP, CPCV, Simulation
- Precise and high speed control of time, voltage, current, etc.
- Interface : IEEE802.3(LAN)
- Current ranges : 10~400A
- Voltage Measurement Accuracy : ±0.03% F.S
- Voltage Resolution : 16bit
- Current Measurement Accuracy : ±0.05%
- Current Resolution : 16bit
- Current Ripple : ≤+0.2% F.S
- Up to 4 Ranges
- Control Interval : 1ms
- Current Rising Time : <1ms
- Input Power Supply : 3 Phase 220Vac 50/60Hz
Specification
PNE Solution can be configured with a wide range of voltage and current ranges and can be fitted with optional hardware to provide a number of additional features and capabilities. Also, It interlocks with hot/cold chamber.
Model Designation | Voltage | Current | Max. Number of Channels | Cabinet Size(W*D*H/mm) |
---|---|---|---|---|
PEHBRC 05-100 | 0~5V | 100 / 50 / 10A | 32 | 1000*1500*2100 |
PEHBRC 05-200 | 0~5V | 200 / 100 / 20 / 10A | 32 | 1000*1500*2100 |
PEHBRC 05-300 | 0~5V | 300 / 150 / 30 / 10A | 32 | 1000*1500*2100 |
PEHBRC 05-400 | 0~5V | 400 / 200 / 40 / 10A | 16 | 1000*1500*2100 |
Application
Cylindrical type
Prismatic type
Pouch type
3 Electrode Pouch Cell
Contact us
- CELL CYCLER